VascX elastic flow-control AV graft and stent

Elastic flow-control for dialysis access

VascX is revolutionizing dialysis access — addressing high-output heart failure and venous stenosis in graft and fistula patients through a patented elastic flow-control platform.

Patented Elastic Flow-Control Technology A Principal Medical Company
The Problem

Standard AV access creates a cardiac burden.

AV access is life-saving, but it is not physiologically free: it creates a permanent low-resistance shunt, increasing venous return and cardiac workload 24 hours a day, every day, for years.

01 / Population
786K
End Stage Renal Disease patients in the US, with 130,000 new patients each year requiring dialysis access
02 / Hemodynamics
30%
of accesses are already clinically (symptomatic), adding ~1,000 cc/min of cardiac output demand — all day, every day
03 / Mortality
50%+
of hemodialysis patients died from heart failure and cardiac-related causes in 2020 — and the average patient lives just three years
The Solution

VascX adds the missing flow-control layer to dialysis access.

  • Patented, elastic flow-control implants reduce high-flow burden while preserving dialysis performance.
  • Platform technology across 90% of access types (grafts and fistulas).
  • Easy adoption: same surgical workflow, same reimbursement.
  • Elasticity matters: accommodates thrombectomy/Fogarty and returns to calibrated profile.
VascX devices with cross-section detail showing 3mm ID elastic coarct and smooth inner lumen
The Platform

Elastic flow-control platform.

A single patented principle — elastic geometric narrowing at the center of the access — restores physiological hemodynamics. Outside dialysis sessions, the narrowing limits excess cardiac flow. During dialysis, it increases the inflow-outflow pressure differential and prevents blood-mixing.

Elastic flow-control mechanism
VASCX · A Principal Medical Company
The Products

Two products. One platform.

Elastic flow-control AV graft
At Implant

Elastic flow-control AV graft

A novel AV graft with a built-in elastic central narrowing that optimizes hemodynamics at implant — no secondary procedures required.

  • 50–70% reduction in flow rate
  • Accommodates intervention & thrombectomy
  • No change to surgeon's workflow
  • No second surgery for flow-control
Elastic flow-control stent
Retrofit

Elastic flow-control stent

An endovascular stent that introduces elastic flow control to existing fistulas and grafts — restoring physiological flow without open surgery.

  • 50–70% reduction in flow rate
  • Accommodates intervention & thrombectomy
  • Minimally invasive endovascular delivery
  • Deployable in fistulas and grafts
Clinical Evidence

Flow control is proven to work.

The VascX platform geometry is similar to — and improves upon — precision banding, the most studied flow-modulation technique in dialysis access.

01 / Patency
90%
Secondary patency at 24 months in precision banding studies — comparable to or better than standard grafts
02 / Outcomes
↓ Stenosis
Significantly lower venous stenosis, thrombosis, and intervention rates versus unbanded AV access
03 / Cardiac
↓ Cardiac Load
Restoration of natural flow reduces excess cardiac output demand — directly addressing the leading cause of patient mortality
[1] Miller, G.A., Goel, N., Friedman, A., et al. (2009). The MILLER banding procedure is an effective method for treating dialysis-associated steal syndrome. Kidney International, 76(9), 962–967.    [2] USRDS 2020 Annual Data Report — End Stage Renal Disease Mortality.
Mission

More years.
Better years.

VascX exists to close the cardiology-nephrology gap that leaves dialysis patients underserved — moving beyond severe-case-only interventions toward a standard of care that protects the heart from day one.

News

Latest from VascX.

Updates on clinical development, publications, and company milestones.

May 21, 2026

VascX flow-control platform highlighted at VASA

Leading access physicians linked high-flow AV grafts and fistulas to cardiac burden and the need for a new category of flow-control dialysis access.

Read the release →
January 2026

Patent portfolio expanded across graft and stent platform

VascX continues to build its intellectual property position across both products.

Learn more →
2025

Proof-of-concept in large-animal pilot with prototype

Non-GLP preclinical study showed 54% flow reduction with prototype device.

Learn more →
Clinical Resources

Learn more about the science and the platform.

Learn more about the clinical problem VascX is addressing and the emerging category of flow-control dialysis access.

Condition high-flow dialysis access → Condition high-output heart failure and dialysis access → Condition access flow reduction → Science cardiac burden of AV fistulas and AV grafts → Technology flow-control dialysis access → Technology elastic flow-control grafts → Technology elastic flow-control stents →
Contact

Get in touch.

We welcome inquiries from clinicians, researchers, investors, and potential partners interested in the VascX platform.

Clinicians
Clinical collaboration, investigator interest, and early access programs
Investors
Series A pipeline, financials, and development roadmap
Partners
Distribution, manufacturing, and licensing inquiries
Media
Press inquiries and interview requests